Material Handling , Bin Fill Ready Mix Concrete

 

Home

Sierra

Sierra 1,2,3

Regal
Overhead Bins 6 Max 8 Max 12 Max
Storage Gates  8 Max 24 Max 64 Max
Belts 2 Max 3 Max 5 Max
Turn Heads   1 Max 1 Max 2 Max
Shuttle belt instead of turn head  No Yes Optional
Bin Emergency High    No Standard Optional
Bin Emergency Low    No Yes Optional
Material Flow Monitoring  Yes  Yes All Belts
Belt Track Monitoring    Yes Yes All Belts
Belt Run Monitoring All Belts All Belts All Belts
Cement Silo Hi & Low Light Display  2 Silo's 4 Silo's 4 Silo's
Priority Bin Fill Standard Standard Standard
Multiple Gate to Bin Assignment    4 per Bin 4 per Bin 16 per Bin
Gate Change, no Material    Standard Standard Standard
Gate Change on Time    No No Standard
Gate Change on Bin Fill Start Standard Standard Standard
Time Feed Any Bin in Manual Mode    No No Standard
Short fill unskipped bins No No Standard
Semi-Automatic operation in manual mode from PC Standard Standard Standard
Automatic Gate & T.H. Timing setup    T.H. Only T.H. Only Standard
Compare Gate & Bin Material before feed    Standard Standard Standard
Specialty Bin(s) in plant    No Standard Standard
Voice Alarm Prompting    Standard Standard Standard
Edit change & Alarm Logging    Standard Standard Standard
Diverter, 2 Positions  No With Shuttle Optional
Remote Diagnostics with factory by modem    Standard Standard Standard
Gate LInking, Gate Blending  No Linking Both
Multiple Operator Stations, on and/ or off site    No Optional Optional
Any screen/operation can be password protected    Standard Standard Standard
PC to Display, monitor & Operate Plant    Standard Standard Standard
Data Backup on 3.5" disk    Standard Standard Standard
Name Material in Plant Bins and Storage Gates Standard Standard Standard
Login Name Required to operate plant    Standard Standard Standard
Bin Automatic Skip if no Material in Storage    Standard Standard Standard
Manual Lights & Switches on Plant wiring Box    Optional Optional Standard
Aggregate Storage Silo fill control    No Optional Optional
Gates to Belt Assignment, up to 3 belts No No Optional
2 Separate Plant Control from 1 PC No Optional Optional
Time Flow any Bin in Automatic mode No No Standard
Time Fill any Bin in Automatic mode No No Standard
Incline Belt Speed Monitor & shutdown No Standard Standard
Automatic Material watering over belt Standard Standard Standard
Automatic Belt Pan watering No No Standard
High & Low Bin Analog Inputs No No Optional


  Download This Document (pdf format)

 

Home ]